Part Number Hot Search : 
GDIAGRA BD7903FS LSZ53S P6002AAL SPE405 393CM 5261B TQ150
Product Description
Full Text Search
 

To Download SG969100 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 S/MOT/SG969100/B/19/03/2004
INVERSEURS DE SENS DE ROTATION MOTOR REVERSER
Le relais SG969100 ( moteur 3kW max sous 400VAC) avec la coupure des 3 phases et l'inversion de 2 , peut etre commande avec une entree type PNP ( automates europeens) avec ou sans tension de commande . Ce modele dispose en plus d'une sortie donnant l'information de fonctionnement du relais dans l'un ou l'autre sens , d'une temporisation reglage entre chaque sens de rotation . Elle peut permettre en particulier de piloter un relais de type SOFT-START ( voir derniere page) . The SG969100 ( max 3Kw motor /400VAC ) relay with the commutation of the 3 phases and the reversing of 2 , has the special feature of a PNP type control , with or without V+ power supply , an output capable of controlling an SMC9 soft-start relay (see last page ) and a independent setting for each rotation direction .
page 1 /5GB
SG969100
3x400VAC 3KW Three legs model
Dimensions / Dimensions:
THREE-PHASE POWER SUPPLY
37
25
5
82,71 0 0 19 90 19
4
39,5
PROTECTIONS
sens 2
4,4 58,4 73,5 40
sens 1
celduc France 6 5 4 3 2 1
Tempo inversion
L1/R U
L2/S V
L3/T W
58,4
69
40
INVERSEUR TRIPHASE SG969100
91 100
19 81 19 9
M3~
Circuit equivalent/Equivalent circuit : Capot de protection/ Cover : reference 1K199000
Internal block diagram :
L1/R 0v
1
L2/R
L3/R
0v S
2
Vcc
47,5
E2 E1 V+ 0v
3 4 5 Insulation (photocouplers) Control logic
6
0v Direction 1 Direction 2
U
V
W
Proud to serve you
All technical caracteristics are subject to change without previous notice. Caracteristiques sujettes a modifications sans preavis.
celduc
r e l a i
s
S/MOT/SG969100/B/19/03/2004
page 2 / 5 F/GB Designed in compliance with standards: ->EN60947-4-2 (V.D.E. 0660 part 109, I.E.C. 158-2) ->EN60947-1 & A11 ->EN60950 (V.D.E. 0805-> office equipment) (Pending approval) ->U.L. 508 (Pending approval) ->c.U.L (Pending approval) Plage de tension de commande / Control voltage range Plage de courant de commande / Control current range Tension de non fonctionnement/ Release voltage LED de visualisation / Display LED
protection en cas de cdes simultanees / protection against simultaneous controls
Control
Uc Ic Ur
tension inverse maxi / Maximum reverse voltage Signal de sortie / Output signal temporisation inversion / Reversing time
Urv S (pin2)
12-30VDC 13-31mA 7VDC Yes Yes 30V max 60VDC 50mA
adjustable 0,06 to 4s
Examples of possible controls
Switch - control
+10 to 30VDC 0V common V+ direction 1 direction 2 60mA max output 0V common
Input diagram :
Logic control 12 to 15 VDC PNP control
5 SG9.
Regul.
Vcc
SG9.
6 5 4 3 2 1 0V common +12 to 15VDC V+ direction 1 direction 2 60mA max output 0V common
SG9.
6 5 4 3 2 1 +10 to 30VDC 0V common V+ direction 1 direction 2 60mA max output 0V common
6 5 4 3 2 1
3/4 2,7V
10k
0V
8,2k 1/6
6,8V
0V Brochage du bornier de commande:
BORNE 1 2 3 4 5 6 DESIGNATION 0v COMMUN SORTIE PNP ENTREE SENS 2 ENTREE SENS 1 ENTREE V+ 0v COMMUN
Pin arrangement on control terminal strip :
TERMINAL 1 2 3 4 5 6 DESCRIPTION 0V COMMON 60mA OUTPUT SUPPLY DIRECTION 2 INPUT DIRECTION 1 INPUT V+ INPUT 0V COMMON
Examples of time diagrams
E1 Control direction 1
E2 Control direction 2
10ms Motor direction 1
10ms
Motor direction 2
Tpo2
Tpo1
Tpo2
Tpo1
Tpo2
Tpo1 : Inversion time from the direction 2 to the direction 1 : 70ms Tpo2 : Inversion time from the direction 1 to the direction 2 : 70ms
Caracteristiques d'entree-sortie (a 20C) / Input-output characteristics (at 20C) Isolement entree-sortie/Input-output isolation @500m Isolement sortie-semelle/Output-case isolation @500m Tension assignee isolement/rated impulse voltage Caracteristiques generales / General characteristics Poids/Weight Plage de temperature de stockage / Storage temperature range Plage de temperature de fonctionnement/Operating temperature range
Ui Ui Uimp
4000 2500 4000
Unit VRMS VRMS V Unit g C C
130g
-40 / +100 -40 / +100
celduc
r e l a i s
www.celduc.com
Rue Ampere B.P. 4 42290 SORBIERS - FRANCE E-Mail : celduc-relais@celduc.com Fax +33 (0) 4 77 53 85 51 Service Commercial France Tel. : +33 (0) 4 77 53 90 20 Sales Dept.For Europe Tel. : +33 (0) 4 77 53 90 21 Sales Dept. Asia : Tel. +33 (0) 4 77 53 90 19
S/MOT/SG969100/B/19/03/2004
page 3 / 5 F/GB Tension nominale/ Standard mains voltage Plage de tension de fonctionnement / Mains voltage range tension crete non repetitive/ Non-repetitive maximum peak voltage Courant AC-53 maxi/ Max. nom. current (AC53a=AC3) @40C Puissance moteur/ 3 pole power motor ( 3x400VAC) Chute directe / Max Direct voltage drop (@Ie) Courant crete non repetitif/ Non repetitive overload current (@ 1 cycle of 10ms) I2t value/ Melting limit (choice of fuse) @10ms Courant minimal de charge / Minimum load current facteur de puissance/ Power factor (@ Ith)
Temps d'ouverture et de temporisation/ Turn on time-reversing time(@50Hz)
Ue Un Up Ie Pn Ud ITSM It Imin Pf ton/trv toff Ilk dv/dt f
2
400 VAC 24-500VAC 1200V 6,6 3kW 1,4VRMS 350A 612 A2s 100 mA 0 up to 1 10ms /adjustable 10ms 5 mARMS 500V/s 25 up to 440Hz
Output
Temps d'ouverture/ Turn off time (@50Hz) Courant de fuite /Maximum leakage current (@Ue/50Hz) dv/dt / Max off state voltage rise Frequence de reseau / Operating frequency range Max conducted immunity level Test accord. to I.E.C.1000-4-4 (bursts) Max conducted immunity level Test acc. to I.E.C.1000-4-5 (el. shocks) Max radiated immunity level Test accord. to I.E.C.1000-4-3 Max electrostatic disch. immunity level Test accord. to I.E.C.1000-4-2 Max conducted emission level (0,84KV direct at output, 4KV with a clamp at input no turn on or damage 2KV in common mode, 1KV in differential mode (Input & output) no turn on or damage
E.M.C.
10V/m
no turn on or damage
8KV in the air / 4KV touching
no turn on or damage
The conducted noise made by SSR depends on the wiring configuration and the load type. Test methods recommended by European E.M.C. standards giving results far from reality, we have chosen to advise the right filter suited for the customer's use: Refer to EMC chapter
<30dBV from 30 up to 230MHz ; <37dBV from 230 up to 1000MHz
Misc.
1,1K/W (1 leg) 5K/W 130g MONTAGE D'UN RELAIS Mounting of a relay on a heatsink
Connect to protective ground. Connecter au conducteur de protection
Must be used only in conjunction with a heatsink mounted in vertical position to help the air flow. Minimum air distances all around the heatsink : 10mm. Doit etre utilise obligatoirement monte sur dissipateur thermique place en position verticale afin de faciliter la circulation de l'air. Distances minimum dans l'air autour du dissipateur : 10mm
91
,5m
m
cc ee ld du l u c c
M4 x 12mm 1,5N.m
Use heat conducting paste. Utiliser de la graisse thermoconductrice.
celduc
r e l a i s
Rue Ampere B.P. 4 42290 SORBIERS - FRANCE E-Mail : celduc-relais@celduc.com Fax +33 (0) 4 77 53 85 51 Service Commercial France Tel. : +33 (0) 4 77 53 90 20 Sales Dept.For Europe Tel. : +33 (0) 4 77 53 90 21 Sales Dept. Asia : Tel. +33 (0) 4 77 53 90 19
40mm
M4 x 12mm 1,5N.m
S/MOT/SG969100/B/19/03/2004
Caracteristiques thermiques / Thermal curves : 30 1,2K/W = WF121100
page 4 / 5 F/GB
30
25
25
Total wasted power (W)
20
20
15 sans dissipateur/ without heatsink 10
15
10
5
5
0 0 2 4 6 8 10 RMS load current (A) 12 0
0 10 20 30 40 50 60 70 80 90 100 Ambient temperature (C)
Courant de surcharge non repetitif :ITSM / Non repetitive surge peak on-state current : ITSM
Fig.3 Surcharge de courant : Itsm (Apeak) = f(t) pour modele 40A(Itsm=350A) Surge current : Itsm (Apeak) = f(t) for 40A models with Itsm =350A 400 Itsm (Apeak) 300 200 100 0 0,01
Surcharge de courant repetitive avec tension reappliquee Repetive surge current with voltage reapplied. Surcharge de courant non repetitive sans tension reappliquee / No repetive surge current without voltage reapplied.
0,1 t(s)
1
10
SSR SELECTION motors soft-staters
REVERSERS + HEATSINK SELECTION IN COMPLIANCE WITH EN60947-4-2 Ferraz fuse type Overload relay type Relays without heatsink Heatsink ambient =40C heatsink =80C 14x51 size / max. rating Klockner-Moeller
for a permanent current
Motor power In motor
(@ 400V)
three legs models 40A
with integrated DIN RAIL adaptor
sans protection court-circuit / no protection in case of short circuit (*)
am 8A/500V am 8A/500V am 12A/500V am 12A/500V am 12A/500V am 12A/500V Z00-2.4 Z00-6 Z00-6 Z00-6 Z00-10 Z00-10
0,75 kW 1,1 kW 1,5 kW 2,2 kW 3 kW 4 kW
2A 2,6A 3,5A 5A 6,6A 8,5A
SG969100 SG969100 SG969100 SG969100 SG969100
-
none none none WF121000 WF121000 WF121000
(*) : Pour une protection court-circuit correcte des relais : utiliser les SG969300 (*) : For a better protection against short-circuit use SG969300
celduc
r e l a i s
www.celduc.com
Rue Ampere B.P. 4 42290 SORBIERS - FRANCE E-Mail : celduc-relais@celduc.com Fax +33 (0) 4 77 53 85 51 Service Commercial France Tel. : +33 (0) 4 77 53 90 20 Sales Dept.For Europe Tel. : +33 (0) 4 77 53 90 21 Sales Dept. Asia : Tel. +33 (0) 4 77 53 90 19
S/MOT/SG969100/B/19/03/2004
page 5 / 5 F/GB
SG969100 + SMC93xxx The SSR reversers can drive directly the soft-start .
THREE PHASE MAIN SUPPLY 400V
+10 to 30VDC 0V common
sens 2 sens 1
celduc France 6 5 4 3 2 1
Tempo inversion
L1/R U
L2/S V
L3/T W
INVERSEUR TRIPHASE SG969100
celduc
France
6 5 4 3 2 1
L1/R
L2/S
L3/T
soft start SMC93500 U V W
V1 V2
M3~
celduc
r e l a i s
www.celduc.com
Rue Ampere B.P. 4 42290 SORBIERS - FRANCE E-Mail : celduc-relais@celduc.com Fax +33 (0) 4 77 53 85 51 Service Commercial France Tel. : +33 (0) 4 77 53 90 20 Sales Dept.For Europe Tel. : +33 (0) 4 77 53 90 21 Sales Dept. Asia : Tel. +33 (0) 4 77 53 90 19


▲Up To Search▲   

 
Price & Availability of SG969100

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X