|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
S/MOT/SG969100/B/19/03/2004 INVERSEURS DE SENS DE ROTATION MOTOR REVERSER Le relais SG969100 ( moteur 3kW max sous 400VAC) avec la coupure des 3 phases et l'inversion de 2 , peut etre commande avec une entree type PNP ( automates europeens) avec ou sans tension de commande . Ce modele dispose en plus d'une sortie donnant l'information de fonctionnement du relais dans l'un ou l'autre sens , d'une temporisation reglage entre chaque sens de rotation . Elle peut permettre en particulier de piloter un relais de type SOFT-START ( voir derniere page) . The SG969100 ( max 3Kw motor /400VAC ) relay with the commutation of the 3 phases and the reversing of 2 , has the special feature of a PNP type control , with or without V+ power supply , an output capable of controlling an SMC9 soft-start relay (see last page ) and a independent setting for each rotation direction . page 1 /5GB SG969100 3x400VAC 3KW Three legs model Dimensions / Dimensions: THREE-PHASE POWER SUPPLY 37 25 5 82,71 0 0 19 90 19 4 39,5 PROTECTIONS sens 2 4,4 58,4 73,5 40 sens 1 celduc France 6 5 4 3 2 1 Tempo inversion L1/R U L2/S V L3/T W 58,4 69 40 INVERSEUR TRIPHASE SG969100 91 100 19 81 19 9 M3~ Circuit equivalent/Equivalent circuit : Capot de protection/ Cover : reference 1K199000 Internal block diagram : L1/R 0v 1 L2/R L3/R 0v S 2 Vcc 47,5 E2 E1 V+ 0v 3 4 5 Insulation (photocouplers) Control logic 6 0v Direction 1 Direction 2 U V W Proud to serve you All technical caracteristics are subject to change without previous notice. Caracteristiques sujettes a modifications sans preavis. celduc r e l a i s S/MOT/SG969100/B/19/03/2004 page 2 / 5 F/GB Designed in compliance with standards: ->EN60947-4-2 (V.D.E. 0660 part 109, I.E.C. 158-2) ->EN60947-1 & A11 ->EN60950 (V.D.E. 0805-> office equipment) (Pending approval) ->U.L. 508 (Pending approval) ->c.U.L (Pending approval) Plage de tension de commande / Control voltage range Plage de courant de commande / Control current range Tension de non fonctionnement/ Release voltage LED de visualisation / Display LED protection en cas de cdes simultanees / protection against simultaneous controls Control Uc Ic Ur tension inverse maxi / Maximum reverse voltage Signal de sortie / Output signal temporisation inversion / Reversing time Urv S (pin2) 12-30VDC 13-31mA 7VDC Yes Yes 30V max 60VDC 50mA adjustable 0,06 to 4s Examples of possible controls Switch - control +10 to 30VDC 0V common V+ direction 1 direction 2 60mA max output 0V common Input diagram : Logic control 12 to 15 VDC PNP control 5 SG9. Regul. Vcc SG9. 6 5 4 3 2 1 0V common +12 to 15VDC V+ direction 1 direction 2 60mA max output 0V common SG9. 6 5 4 3 2 1 +10 to 30VDC 0V common V+ direction 1 direction 2 60mA max output 0V common 6 5 4 3 2 1 3/4 2,7V 10k 0V 8,2k 1/6 6,8V 0V Brochage du bornier de commande: BORNE 1 2 3 4 5 6 DESIGNATION 0v COMMUN SORTIE PNP ENTREE SENS 2 ENTREE SENS 1 ENTREE V+ 0v COMMUN Pin arrangement on control terminal strip : TERMINAL 1 2 3 4 5 6 DESCRIPTION 0V COMMON 60mA OUTPUT SUPPLY DIRECTION 2 INPUT DIRECTION 1 INPUT V+ INPUT 0V COMMON Examples of time diagrams E1 Control direction 1 E2 Control direction 2 10ms Motor direction 1 10ms Motor direction 2 Tpo2 Tpo1 Tpo2 Tpo1 Tpo2 Tpo1 : Inversion time from the direction 2 to the direction 1 : 70ms Tpo2 : Inversion time from the direction 1 to the direction 2 : 70ms Caracteristiques d'entree-sortie (a 20C) / Input-output characteristics (at 20C) Isolement entree-sortie/Input-output isolation @500m Isolement sortie-semelle/Output-case isolation @500m Tension assignee isolement/rated impulse voltage Caracteristiques generales / General characteristics Poids/Weight Plage de temperature de stockage / Storage temperature range Plage de temperature de fonctionnement/Operating temperature range Ui Ui Uimp 4000 2500 4000 Unit VRMS VRMS V Unit g C C 130g -40 / +100 -40 / +100 celduc r e l a i s www.celduc.com Rue Ampere B.P. 4 42290 SORBIERS - FRANCE E-Mail : celduc-relais@celduc.com Fax +33 (0) 4 77 53 85 51 Service Commercial France Tel. : +33 (0) 4 77 53 90 20 Sales Dept.For Europe Tel. : +33 (0) 4 77 53 90 21 Sales Dept. Asia : Tel. +33 (0) 4 77 53 90 19 S/MOT/SG969100/B/19/03/2004 page 3 / 5 F/GB Tension nominale/ Standard mains voltage Plage de tension de fonctionnement / Mains voltage range tension crete non repetitive/ Non-repetitive maximum peak voltage Courant AC-53 maxi/ Max. nom. current (AC53a=AC3) @40C Puissance moteur/ 3 pole power motor ( 3x400VAC) Chute directe / Max Direct voltage drop (@Ie) Courant crete non repetitif/ Non repetitive overload current (@ 1 cycle of 10ms) I2t value/ Melting limit (choice of fuse) @10ms Courant minimal de charge / Minimum load current facteur de puissance/ Power factor (@ Ith) Temps d'ouverture et de temporisation/ Turn on time-reversing time(@50Hz) Ue Un Up Ie Pn Ud ITSM It Imin Pf ton/trv toff Ilk dv/dt f 2 400 VAC 24-500VAC 1200V 6,6 3kW 1,4VRMS 350A 612 A2s 100 mA 0 up to 1 10ms /adjustable 10ms 5 mARMS 500V/s 25 up to 440Hz Output Temps d'ouverture/ Turn off time (@50Hz) Courant de fuite /Maximum leakage current (@Ue/50Hz) dv/dt / Max off state voltage rise Frequence de reseau / Operating frequency range Max conducted immunity level Test accord. to I.E.C.1000-4-4 (bursts) Max conducted immunity level Test acc. to I.E.C.1000-4-5 (el. shocks) Max radiated immunity level Test accord. to I.E.C.1000-4-3 Max electrostatic disch. immunity level Test accord. to I.E.C.1000-4-2 Max conducted emission level (0,8 E.M.C. 10V/m no turn on or damage 8KV in the air / 4KV touching no turn on or damage The conducted noise made by SSR depends on the wiring configuration and the load type. Test methods recommended by European E.M.C. standards giving results far from reality, we have chosen to advise the right filter suited for the customer's use: Refer to EMC chapter <30dBV from 30 up to 230MHz ; <37dBV from 230 up to 1000MHz Misc. 1,1K/W (1 leg) 5K/W 130g MONTAGE D'UN RELAIS Mounting of a relay on a heatsink Connect to protective ground. Connecter au conducteur de protection Must be used only in conjunction with a heatsink mounted in vertical position to help the air flow. Minimum air distances all around the heatsink : 10mm. Doit etre utilise obligatoirement monte sur dissipateur thermique place en position verticale afin de faciliter la circulation de l'air. Distances minimum dans l'air autour du dissipateur : 10mm 91 ,5m m cc ee ld du l u c c M4 x 12mm 1,5N.m Use heat conducting paste. Utiliser de la graisse thermoconductrice. celduc r e l a i s Rue Ampere B.P. 4 42290 SORBIERS - FRANCE E-Mail : celduc-relais@celduc.com Fax +33 (0) 4 77 53 85 51 Service Commercial France Tel. : +33 (0) 4 77 53 90 20 Sales Dept.For Europe Tel. : +33 (0) 4 77 53 90 21 Sales Dept. Asia : Tel. +33 (0) 4 77 53 90 19 40mm M4 x 12mm 1,5N.m S/MOT/SG969100/B/19/03/2004 Caracteristiques thermiques / Thermal curves : 30 1,2K/W = WF121100 page 4 / 5 F/GB 30 25 25 Total wasted power (W) 20 20 15 sans dissipateur/ without heatsink 10 15 10 5 5 0 0 2 4 6 8 10 RMS load current (A) 12 0 0 10 20 30 40 50 60 70 80 90 100 Ambient temperature (C) Courant de surcharge non repetitif :ITSM / Non repetitive surge peak on-state current : ITSM Fig.3 Surcharge de courant : Itsm (Apeak) = f(t) pour modele 40A(Itsm=350A) Surge current : Itsm (Apeak) = f(t) for 40A models with Itsm =350A 400 Itsm (Apeak) 300 200 100 0 0,01 Surcharge de courant repetitive avec tension reappliquee Repetive surge current with voltage reapplied. Surcharge de courant non repetitive sans tension reappliquee / No repetive surge current without voltage reapplied. 0,1 t(s) 1 10 SSR SELECTION motors soft-staters REVERSERS + HEATSINK SELECTION IN COMPLIANCE WITH EN60947-4-2 Ferraz fuse type Overload relay type Relays without heatsink Heatsink ambient =40C heatsink =80C 14x51 size / max. rating Klockner-Moeller for a permanent current Motor power In motor (@ 400V) three legs models 40A with integrated DIN RAIL adaptor sans protection court-circuit / no protection in case of short circuit (*) am 8A/500V am 8A/500V am 12A/500V am 12A/500V am 12A/500V am 12A/500V Z00-2.4 Z00-6 Z00-6 Z00-6 Z00-10 Z00-10 0,75 kW 1,1 kW 1,5 kW 2,2 kW 3 kW 4 kW 2A 2,6A 3,5A 5A 6,6A 8,5A SG969100 SG969100 SG969100 SG969100 SG969100 - none none none WF121000 WF121000 WF121000 (*) : Pour une protection court-circuit correcte des relais : utiliser les SG969300 (*) : For a better protection against short-circuit use SG969300 celduc r e l a i s www.celduc.com Rue Ampere B.P. 4 42290 SORBIERS - FRANCE E-Mail : celduc-relais@celduc.com Fax +33 (0) 4 77 53 85 51 Service Commercial France Tel. : +33 (0) 4 77 53 90 20 Sales Dept.For Europe Tel. : +33 (0) 4 77 53 90 21 Sales Dept. Asia : Tel. +33 (0) 4 77 53 90 19 S/MOT/SG969100/B/19/03/2004 page 5 / 5 F/GB SG969100 + SMC93xxx The SSR reversers can drive directly the soft-start . THREE PHASE MAIN SUPPLY 400V +10 to 30VDC 0V common sens 2 sens 1 celduc France 6 5 4 3 2 1 Tempo inversion L1/R U L2/S V L3/T W INVERSEUR TRIPHASE SG969100 celduc France 6 5 4 3 2 1 L1/R L2/S L3/T soft start SMC93500 U V W V1 V2 M3~ celduc r e l a i s www.celduc.com Rue Ampere B.P. 4 42290 SORBIERS - FRANCE E-Mail : celduc-relais@celduc.com Fax +33 (0) 4 77 53 85 51 Service Commercial France Tel. : +33 (0) 4 77 53 90 20 Sales Dept.For Europe Tel. : +33 (0) 4 77 53 90 21 Sales Dept. Asia : Tel. +33 (0) 4 77 53 90 19 |
Price & Availability of SG969100 |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |